Shift Solenoid Valve O/P Test

NOTE: Keep all foreign particles out of the transmission.

2. Shift Solenoid Valve O/P - HDS Function Test

1.
Select the Shift Solenoid Valve O/P in the Miscellaneous Test Menu with the HDS.

2.
Check that Shift Sol O/P is indicated to ON and OFF by three seconds.

If indicated to ON and OFF, the solenoid valve O/P is OK. The test is complete, disconnect the HDS.
If no indicated to ON and OFF, go to the next step, and test the shift solenoid valve O/P.

3.
Turn the vehicle to the OFF (LOCK) mode.

3. Shift Solenoid Valve O/P - Internal Resistance Check



2.
Disconnect the connector (A).

3.
Measure the shift solenoid valve O/P resistance between the connector (B) terminal No. 1 and body ground.

Standard: 10.6?13.5 ?
If the resistance is within the standard, go to the next step and check the shift solenoid valve O/P operation.
If the resistance is out of the standard, replace the shift solenoid valve O/P.

4. Shift Solenoid Valve O/P - Operation Check



2.
Connect a tube (B) to the shift solenoid valve O/P.

3.
Blow air into the tube.

If the air goes out of the port (C), go to step 4.
If the air does not go out of the port (C), replace the shift solenoid valve O/P.

4.
Connect a jumper wire from the positive battery terminal to the shift solenoid valve O/P (B) connector terminal No. 1, and connect another jumper wire from the negative battery terminal to the shift solenoid valve O/P body. Blow air into the tube (A).

If the air goes out of the port (C), replace the shift solenoid valve O/P.
If the air does not go out of the port (C), repair the wire between the shift solenoid valve O/P and the PCM.

5. All Removed Parts - Install

1.
Install the parts in the reverse order of removal.